electrical installations Archives - Professional Electrician https://professional-electrician.com/tag/electrical-installations/ the latest news, products, tools and info for UK electricians Wed, 05 Feb 2025 11:42:13 +0000 en-GB hourly 1 Made 2 Measure: Is there a simple and reliable way of filling in electrical installation test certificates? https://professional-electrician.com/technical/made-2-measure-is-there-a-simple-and-reliable-way-of-filling-in-electrical-installation-test-certificates/ Thu, 06 Feb 2025 08:00:05 +0000 https://professional-electrician.com/?p=49911 Made 2 Measure: Is there a simple and reliable way of filling in electrical installation test certificates?

Working on your own? Need some technical advice? Don’t know where to turn? The technical team at Megger answers the latest technical query from end users. YOU ASK: WHEN I’M TESTING ELECTRICAL INSTALLATIONS, I HATE FILLING IN TEST CERTIFICATES BY HAND. IT TAKES AGES AND IT’S EASY TO MAKE MISTAKES. IS THERE A SIMPLER AND ...

The post Made 2 Measure: Is there a simple and reliable way of filling in electrical installation test certificates? appeared first on Professional Electrician.

]]>
Spelsberg TKS enclosures provide plug-and-play electrical installation for construction projects https://professional-electrician.com/products/spelsberg-tks-enclosures-provide-plug-and-play-electrical-installation-for-construction-projects/ Thu, 30 Jan 2025 10:00:39 +0000 https://professional-electrician.com/?p=50035 Spelsberg TKS enclosures provide plug-and-play electrical installation for construction projects

With the pressures of modern construction projects, many contractors need electrical installation solutions that combine speed, safety and value. Spelsberg’s recently launched range of TKS enclosures meets these requirements, featuring pre-assembled components and pluggable systems tailored to each customer. Consequently, users can expect simple, efficient and fault-free installations. What sets the TKS range apart from ...

The post Spelsberg TKS enclosures provide plug-and-play electrical installation for construction projects appeared first on Professional Electrician.

]]>
How can earth electrode resistance be improved as part of a planned approach to installation? https://professional-electrician.com/technical/how-can-earth-electrode-resistance-be-improved-as-part-of-a-planned-approach-to-installation/ Wed, 22 Jan 2025 08:00:19 +0000 https://professional-electrician.com/?p=49545 How can earth electrode resistance be improved as part of a planned approach to installation?

It can be difficult for an electrical contractor to determine whether a single electrode will be sufficient to be able to gain an adequate value of resistance prior to its installation and test. Here, Jake Green Head of Technical Engagement, Scolmore Group (owners of the Unicrimp brand) looks at how the earth electrode resistance might ...

The post How can earth electrode resistance be improved as part of a planned approach to installation? appeared first on Professional Electrician.

]]>
Why should you take time to properly design an electrical system? https://professional-electrician.com/technical/why-should-you-design-an-electrical-system/ Wed, 04 Sep 2024 10:00:23 +0000 https://professional-electrician.com/?p=47978 Why should you take time to properly design an electrical system?

Raphael Magnus, Managing Director at Safe-Electric, looks at the legal and ethical reasons that dictate the value of a properly designed electrical system. In my experience, too many electricians don’t bother designing, preferring instead to use the old ‘guestimate’ method while completely ignoring that statutory document that so few take any notice of – HSR-25 ...

The post Why should you take time to properly design an electrical system? appeared first on Professional Electrician.

]]>
The Sealing of Wiring Systems: Preventing Interstitial Condensation | NAPIT https://professional-electrician.com/technical/the-sealing-of-wiring-systems-preventing-interstitial-condensation-napit/ Wed, 24 Jul 2024 07:00:57 +0000 https://professional-electrician.com/?p=47123 The Sealing of Wiring Systems: Preventing Interstitial Condensation | NAPIT

The experts at NAPIT discuss site preparation and resistance to both contaminants and moisture. BS 7671 and Building Regulations The sealing of wiring systems is detailed in Regulation 527.2.1, which specifies the requirements for wiring systems that pass through building construction, such as floors, walls, roofs, ceilings, partitions and cavity barriers. Although this regulation is ...

The post The Sealing of Wiring Systems: Preventing Interstitial Condensation | NAPIT appeared first on Professional Electrician.

]]>
How to determine voltage drop limits within electrical installations | NAPIT https://professional-electrician.com/technical/how-to-determine-voltage-drop-limits-within-electrical-installations-napit/ Wed, 26 Jun 2024 07:00:17 +0000 https://professional-electrician.com/?p=46956 How to determine voltage drop limits within electrical installations | NAPIT

Frank Bertie, Chief Technical Officer at NAPIT, explains how to establish voltage drop limits within electrical installations. BS 7671 and requirements for voltage drop The topic of voltage drop is covered within section 525 of BS 7671 as well as in Appendix 4 section 6.4, where details are provided regarding the requirements and maximum limitations ...

The post How to determine voltage drop limits within electrical installations | NAPIT appeared first on Professional Electrician.

]]>
What are the requirements for disconnecting all live conductors? | Hager https://professional-electrician.com/technical/what-are-the-requirements-for-disconnecting-all-live-conductors-hager/ Wed, 12 Jun 2024 07:00:47 +0000 https://professional-electrician.com/?p=46945 What are the requirements for disconnecting all live conductors? | Hager

Hager’s Technical Training Manager, Paul Chaffers, shares the importance of observing protective device terminal markings and discusses the requirements for disconnecting all live conductors, including the neutral conductor for certain applications. Usually, we consider the current flowing through a protective device to be in one direction only, i.e. from the distribution board to the load. ...

The post What are the requirements for disconnecting all live conductors? | Hager appeared first on Professional Electrician.

]]>
Why are RCD sockets still popular? | Timeguard https://professional-electrician.com/features/why-are-rcd-sockets-still-popular-timeguard/ Tue, 28 May 2024 10:00:17 +0000 https://professional-electrician.com/?p=46522 Why are RCD sockets still popular? | Timeguard

Why are RCD sockets still popular? Neil Chapman, Sales Director at Timeguard, offers his thoughts. The 18th Edition gives us detailed information on the different types of RCDs These regulations apply to the design and verification of electrical installations as well as any additional and/or alteration of existing installations of sockets rated to a maximum ...

The post Why are RCD sockets still popular? | Timeguard appeared first on Professional Electrician.

]]>
The use of electrical accessories in accordance with Approved Document M1 and M2 | Scolmore https://professional-electrician.com/features/the-use-of-electrical-accessories-in-accordance-with-approved-document-m1-and-m2-scolmore/ Mon, 15 Apr 2024 07:00:29 +0000 https://professional-electrician.com/?p=46179 The use of electrical accessories in accordance with Approved Document M1 and M2 | Scolmore

The experts at Scolmore provide guidance for the use of electrical accessories in accordance with Approved Document M – access to and use of buildings. Approved documents (AD) provide practical guidance about how to comply with the requirements of The Building Regulations for England and Wales (where relevant). Under schedule 1, Part M of the ...

The post The use of electrical accessories in accordance with Approved Document M1 and M2 | Scolmore appeared first on Professional Electrician.

]]>
Schneider Electric Unveils Next Generation Acti9 Active Modular Circuit Protection Range for the UK Market https://professional-electrician.com/products/schneider-electric-unveils-next-generation-acti9-active-modular-circuit-protection-range-for-the-uk-market/ Wed, 14 Feb 2024 11:00:53 +0000 https://professional-electrician.com/?p=45592 Schneider Electric Unveils Next Generation Acti9 Active Modular Circuit Protection Range for the UK Market

Schneider Electric has developed a modular circuit protection range tailored for the UK market – Acti9 Active. Schneider Electric’s innovative solution has revolutionised the future of electrical installations across higher risk residential buildings, HMO’s, Office Buildings and care homes, catering to the evolving sustainable needs of electricians, facilities managers and design firms. Compliant with the ...

The post Schneider Electric Unveils Next Generation Acti9 Active Modular Circuit Protection Range for the UK Market appeared first on Professional Electrician.

]]>