Technical advice Archives - Professional Electrician https://professional-electrician.com/tag/technical-advice/ the latest news, products, tools and info for UK electricians Fri, 01 Mar 2024 15:17:50 +0000 en-GB hourly 1 Safe isolation: Selection and use of the right equipment | Martindale Electric https://professional-electrician.com/technical/safe-isolation-selection-and-use-of-the-right-equipment-martindale-electric/ Mon, 04 Mar 2024 08:00:55 +0000 https://professional-electrician.com/?p=45685 Safe isolation: Selection and use of the right equipment | Martindale Electric

Steve Dunning, Managing Director of Martindale Electric, explains the importance of safe isolation and why using the right equipment is an absolute must. Safe isolation procedures are necessary to ensure that workers on-site are not exposed to danger when working on or near live electrical systems. There have been incidents where failure to use safe ...

The post Safe isolation: Selection and use of the right equipment | Martindale Electric appeared first on Professional Electrician.

]]>
Made 2 Measure: Can you suggest a Multimeter that meets all my requirements? https://professional-electrician.com/technical/made-2-measure-can-you-suggest-a-multimeter-that-meets-all-my-requirements/ Fri, 23 Feb 2024 08:00:39 +0000 https://professional-electrician.com/?p=45183 Made 2 Measure: Can you suggest a Multimeter that meets all my requirements?

Working on your own? Need some technical advice? Don’t know where to turn? The technical team at Megger answers the latest technical query from end users. YOU ASK: I’M LOOKING FOR A NEW MULTIMETER. I WANT SOMETHING THAT’S RUGGED, RELIABLE, SMALL ENOUGH TO CARRY IN MY POCKET AND YET OFFERS A COMPREHENSIVE RANGE OF FUNCTIONS. ...

The post Made 2 Measure: Can you suggest a Multimeter that meets all my requirements? appeared first on Professional Electrician.

]]>
Different installation methods and the mechanical protection requirements for each | NAPIT https://professional-electrician.com/technical/different-installation-methods-and-the-mechanical-protection-requirements-for-each-napit/ Mon, 05 Feb 2024 08:00:16 +0000 https://professional-electrician.com/?p=45207 Different installation methods and the mechanical protection requirements for each | NAPIT

The technical experts at NAPIT look at different installation methods and the mechanical protection requirements for each. Installation or wiring methods? Whenever we speak to contractors or they ask our advice on an installation or wiring type, there is often some confusion over the different installation methods and how they can be used. Let’s be ...

The post Different installation methods and the mechanical protection requirements for each | NAPIT appeared first on Professional Electrician.

]]>
Made 2 Measure: How can i complete electrical certificates digitally? | Megger https://professional-electrician.com/technical/made-2-measure-how-can-i-complete-electrical-certificates-digitally/ Fri, 26 Jan 2024 11:00:26 +0000 https://professional-electrician.com/?p=44880 Made 2 Measure: How can i complete electrical certificates digitally? | Megger

Working on your own? Need some technical advice? Don’t know where to turn? The technical team at Megger answers the latest technical query from end users. YOU ASK: I WANT TO MOVE FROM HANDWRITTEN ELECTRICAL CERTIFICATES TO COMPLETING THEM DIGITALLY OR ONLINE. I HAVE SEVERAL EMPLOYEES WHO NEED TO COMPLETE THE CERTIFICATES, SO I AM ...

The post Made 2 Measure: How can i complete electrical certificates digitally? | Megger appeared first on Professional Electrician.

]]>
Dr. Zzeus Q&A: How do you calculate the resistance of a fire alarm cable? https://professional-electrician.com/technical/dr-zzeus-qa-how-do-you-measure-the-resistance-of-a-fire-alarm-cable/ Wed, 24 Jan 2024 08:00:03 +0000 https://professional-electrician.com/?p=44915 Dr. Zzeus Q&A: How do you calculate the resistance of a fire alarm cable?

In this regular column, ‘Dr Zzeus’ Tom Brookes, MD of Zzeus Training and chairman of the FSA, answers your questions related to fire safety compliance. This month I’m going to answer two questions relating to the skills of fire alarm and security installers: 1. How do you measure the resistance of a cable? 2. How ...

The post Dr. Zzeus Q&A: How do you calculate the resistance of a fire alarm cable? appeared first on Professional Electrician.

]]>
Made 2 Measure: What is the easiest way to carry out tests on lighting circuits? https://professional-electrician.com/technical/made-2-measure-what-is-the-easiest-way-to-carry-out-tests-on-lighting-circuits/ Thu, 14 Dec 2023 11:00:01 +0000 https://professional-electrician.com/?p=44710 Made 2 Measure: What is the easiest way to carry out tests on lighting circuits?

Working on your own? Need some technical advice? Don’t know where to turn? The technical team at Megger answers the latest technical query from end users. YOU ASK: I OFTEN WASTE A LOT OF TIME WHEN I’M WORKING ON LIGHTING CIRCUITS BECAUSE I NEED TO TAKE THE FITTINGS OR LAMP HOLDERS APART TO GET AT ...

The post Made 2 Measure: What is the easiest way to carry out tests on lighting circuits? appeared first on Professional Electrician.

]]>
Dr. Zzeus Q&A: What is the best way to reduce false alarms going off in hotel bedrooms? https://professional-electrician.com/technical/dr-zzeus-qa-what-is-the-best-way-to-reduce-false-alarms-going-off-in-hotel-bedrooms/ Mon, 27 Nov 2023 10:00:49 +0000 https://professional-electrician.com/?p=44118 Dr. Zzeus Q&A: What is the best way to reduce false alarms going off in hotel bedrooms?

In this regular column, ‘Dr Zzeus’ Tom Brookes, MD of Zzeus Training and chairman of the FSA, answers your questions related to fire safety compliance. Q. We keep getting false alarms in hotel bedrooms, usually caused by steam or deodorants/hairsprays. The fire service is now threatening the hotel with being in special measures. What should ...

The post Dr. Zzeus Q&A: What is the best way to reduce false alarms going off in hotel bedrooms? appeared first on Professional Electrician.

]]>
Made 2 Measure: What is the best way to locate and trace buried cables? https://professional-electrician.com/technical/made-2-measure-what-is-the-best-way-to-locate-and-trace-buried-cables/ Tue, 21 Nov 2023 08:00:00 +0000 https://professional-electrician.com/?p=44114 Made 2 Measure: What is the best way to locate and trace buried cables?

Working on your own? Need some technical advice? Don’t know where to turn? The technical team at Megger answers the latest technical query from end users. YOU ASK: I’M WORKING ON AN ELECTRICAL INSTALLATION THAT HAS SOME CABLES THAT ARE BURIED ABOUT A METRE UNDERGROUND. UNFORTUNATELY, NOBODY HAS ANY RELIABLE INFORMATION ABOUT WHERE THE BURIED ...

The post Made 2 Measure: What is the best way to locate and trace buried cables? appeared first on Professional Electrician.

]]>
Made 2 Measure: what is the easiest and safest way of completing R1 and R2 testing at sockets? https://professional-electrician.com/technical/made-2-measure-what-is-the-easiest-and-safest-way-of-completing-r1-and-r2-testing-at-sockets/ Mon, 25 Sep 2023 07:00:41 +0000 https://professional-electrician.com/?p=43269 Made 2 Measure: what is the easiest and safest way of completing R1 and R2 testing at sockets?

Working on your own? Need some technical advice? Don’t know where to turn? The technical team at Megger answers the latest technical query from end users. YOU ASK: I’M LOOKING FOR A FAST AND EASY WAY OF COMPLETING R2 AND R1+R2 TESTING AT SOCKETS WITHOUT HAVING TO REMOVE THE FASCIA FROM THE WALL TO GET ...

The post Made 2 Measure: what is the easiest and safest way of completing R1 and R2 testing at sockets? appeared first on Professional Electrician.

]]>
EAWR and BS 7671: can one help the other? | Paul Skyrme https://professional-electrician.com/technical/eawr-and-bs-7671-can-one-help-the-other-paul-skyrme/ Fri, 08 Sep 2023 07:00:49 +0000 https://professional-electrician.com/?p=43262 EAWR and BS 7671: can one help the other? | Paul Skyrme

In this article, produced for PE before his recent passing, the late Paul Skyrme looks at the relationship between the Electricity at Work Regulations and BS 7671. This article intends to explain the inter-relationship between standards and legislation, using BS 7671 and the Electricity at Work Regulations as the reference point. Firstly, it should remembered ...

The post EAWR and BS 7671: can one help the other? | Paul Skyrme appeared first on Professional Electrician.

]]>